LM2907 charge-pump filter experiment

Before connecting any input or output cables, connect the RIGOL DHO804’s rear Ground Terminal to earth ground using the supplied ground cable, as required by the DHO800 User Guide. Its Type-C power input does not ground the instrument through the power cord. Use the supplied power adapter and keep the AFG1022’s and SPD3303X’s protective earth connected. The G0 signal-return connections described below do not replace this separate chassis earth lead.

The article describes the 12 V fixture, all eight pins, the four 200/600 Hz
generator runs and the oscilloscope settings. Fit only one C2 per pair of runs.
Use the original SVG or full-size PNG while making circuit connections.

Copy observations-blank.csv to observations.csv. Fill four measured rails
and four distinct trace filenames from the same directory. Export every
retained simultaneous sample into CSV with header time_s,tach_v,cp2_v.
Keep native raw exports separately. Do not enter the synthetic test numbers.

  python3 pump_response.py observations.csv
  python3 test_pump_response.py

Exit 0 means all contrasts pass the fixture screens. Exit 3 identifies
unresolved capture/comparison evidence. Exit 2 identifies invalid input.
The host tests generate temporary in-memory-defined waveforms, not bench data.
No target firmware is needed.