Place a copper screen between a driven plate and a sensitive plate, then change only the screen’s connection to the common reference. Keep every plate, lead and probe in place. Compare the pickup with the screen floating, grounded and floating again. A source-zero recording provides a separate background check.

The experiment uses a 10 kilohertz (kHz) sine wave, making 10,000 cycles per second, at about 4 V peak-to-peak (Vpp), a high-resistance sensing node and two oscilloscope channels. It measures the transfer of this particular open three-plate fixture. Plate geometry, edge fields, wiring and probe loading all participate in the result.

Before connecting any input or output cables, connect the RIGOL DHO804’s rear Ground Terminal to earth ground using the supplied ground cable, as required by the DHO800 User Guide. Its Type-C power input does not ground the instrument through the power cord. Use the supplied power adapter and keep the AFG1022’s protective earth connected. The G0 signal-return connections described below do not replace this separate chassis earth lead.

Follow the capacitive current path

Capacitive coupling transfers changing charge through an electric field between conductors. Two nearby conductors form a capacitance even when they have no wired connection. A changing source voltage drives a small displacement current through that capacitance. A high-resistance receiver converts the current into a measurable voltage.

i(t) = C × dv(t)/dt
For a sine wave, Ipeak = 2πfC × Vpeak

A screen is an interposed conductor whose potential and return path change the coupling. When this middle foil is floating, capacitances to the source, receiver and surroundings determine its voltage. Connecting it to G0 provides a short return path for capacitively coupled current. The receiver still sees edge and wiring paths around the finite screen.

G0 is the common zero-volt reference joining the generator’s signal return, the sensing resistor and both probe returns. Connect the screen to that same point through its own short lead. This keeps screen current out of the sensitive resistor’s return route.

Build one fixed three-plate fixture

Use 3M Copper Foil EMI Shielding Tape 1181 wide enough to cut a 45 mm square. EMI means electromagnetic interference, unwanted coupling between circuits. The current Rev B data sheet, June 2021, specifies a nominal 0.036 mm copper backing and about 0.066 mm total tape thickness with conductive acrylic adhesive. Make electrical connections to the exposed copper and verify them directly.

Cut two 25 ×25 mm outer electrodes and one 45 ×45 mm middle screen. Mount them flat and parallel in insulating edge frames. Center the outer squares on the middle square. Set each foil-to-screen spacing to 3.0 mm, giving 6.0 mm between the outer foils. Record actual dimensions, centering and gaps. Keep bulky supports outside the central overlapping area where practical.

The drawn horizontal spacing is expanded to make the wiring clear. Use the labeled dimensions for construction. The middle screen stays in position for every recording. Its ground lead also stays attached to the copper, with a removable link J at the G0 end. Route that lead away from the sensing lead and keep it short, around 30 mm or less. Touch only the remote link while changing state, then remove hands and tools from the field before capture.

A 25-by-25-millimetre drive plate and sense plate remain 6 millimetres apart, with a 45-by-45-millimetre screen centered between them. The screen’s link J connects to G0. A generator drives through 1 kilohm, while the sense node has 1 megohm to G0. Two probe tips monitor DRIVE and SENSE, with both returns at G0. Separate calculated plots magnify grounded pickup.
All ground symbols denote G0. CH1 and CH2 mark the probe-tip contacts, with both probe returns at G0. The geometry and lead positions stay fixed while J changes. The constructed plots use the network values below, with the grounded panel on a magnified vertical scale. Horizontal spacing in the side view is expanded for wiring clarity. The drawing omits the DHO804 power adapter and separate chassis earth lead; connect them as described before adding any input or output cables. Full-size PNG · Editable SVG

Wire the receiver and the common return

Drive the first outer plate from Tektronix AFG1022 channel 1 through a Vishay MRS25 1 kΩ ±1% resistor. The ohm (Ω) is the unit of resistance, with 1 kilohm (kΩ) equal to 1000 Ω and 1 megohm (MΩ) equal to one million Ω. Its source series resistor limits current during a wiring mistake and has negligible voltage drop under the intended capacitive load. Scope CH1 touches DRIVE at the plate side of this resistor.

The second outer plate connects to a Vishay MRS25 1 MΩ ±1% resistor to G0. Scope CH2 touches this SENSE node. Use a RIGOL DHO804 with two compensated PVP2350 probes in 10× mode. Their grounded returns both connect to G0. The generator’s Bayonet Neill–Concelman (BNC) connector has a signal center conductor and an outer shell that returns to G0.

The sensing probe adds approximately 10 MΩ ±1% and 10 pF ±5 pF from SENSE to G0. A picofarad (pF) is 10⁻¹² farad. The 1 MΩ resistor and 10 MΩ probe combine to about 0.909 MΩ. Reactance is opposition to alternating current due to capacitance or inductance. At 10 kHz, 10 pF alone has a reactance magnitude of about 1.59 MΩ. That probe capacitance is therefore relevant to the measured phase and amplitude.

Before wiring the source and sensing resistor, check that the foil electrodes are electrically separate. After wiring, verify the unpowered 1 MΩ return with the SENSE probe tip lifted, then return it to the same pad. An attached 10 MΩ probe would give about 0.909 MΩ in parallel. Inspect for a short between SENSE and the screen. With J closed and the source off, measure the screen-to-G0 contact with a Fluke 87V MAX. Require a low, stable resistance below 1 Ω, accounting for the meter leads. This confirms the actual clip or joint.

Open J for the floating condition. The screen’s existing lead remains physically routed in the same place. Close J for the grounded condition. Keep the generator shell, probe returns and sensing resistor return connected throughout. Use the same G0 star point and preserve the receiver wiring.

Estimate the scale of the pickup

An ideal parallel-plate estimate for the two outer 25 mm squares, separated by 6 mm of air, gives C ≈ ε0A/d ≈ 0.922 pF. Here ε0 is air’s approximate permittivity, about 8.854 ×10⁻¹² farad per metre. At 10 kHz and a 2 V source peak, this capacitance corresponds to roughly 0.116 µA peak before accounting for the receiver network.

This is a scale estimate. The gap is a substantial fraction of the plate width, so fringing fields matter. The middle screen, its lead, probe capacitance, supports and surrounding objects also change the network. Use the measured transfer for this fixture instead of deriving an absolute capacitance from the simple plate formula.

The constructed example uses 1.8 pF from DRIVE to screen, 1.8 pF from screen to SENSE, 0.3 pF from screen to G0, 0.02 pF direct DRIVE-to-SENSE coupling and 12 pF total SENSE-to-G0 capacitance. The last value includes the probe and an illustrative wiring contribution. These are model parameters, separate from the geometry estimate.

Calculated 10 kHz network with actual DRIVE = 4.00 Vpp
QuantityFloating screenGrounded screen
Sense peak78.054 mV1.793 mV
Transfer magnitude0.0390270.000897
Sense minus drive phase+53.43°+51.71°

The noiseless model’s amplitude ratio is about 0.02298, or a 32.77 dB reduction. A decibel (dB) expresses an amplitude ratio as 20 log10 of that ratio. The physical fixture can give a different result. The analyzer uses additional declared background and resolution allowances before qualifying a reduction.

Establish the source-zero background explicitly

  1. Set the generator to its direct-current (DC) function at 0 V, with the output enabled. Verify the actual DRIVE plate is within ±10 mV of G0. This defined low-impedance source condition supplies the blank.
  2. Keep J open, with the geometry, lead routing and probes in their floating-screen positions. Use Auto triggering or free-running acquisition for the blank, because the source sine is absent.
  3. Record blank.csv, a comma-separated values (CSV) file, with both channels in the same vertical settings used for the active captures. The analyzer later fits this record at the measured active source frequency. It checks the blank’s source alternating-current (AC) component as well as its DC mean.
  4. Configure the generator for a 10.000 kHz sine, zero DC offset and high-impedance (High Z) amplitude display. Set approximately 4 Vpp, then verify actual DRIVE is 3.8–4.2 Vpp. The physical output resistance remains typically 50 Ω.
  5. Capture floating.csv with J open. Disable the generator output before closing J, then re-enable the same sine settings and capture grounded.csv. Disable it before reopening J, then capture restore.csv.

During the two link changes, the source is disabled for handling. The separate blank uses the enabled DC-zero source verified at the plate. Keep the original captures and a record of settings in the blank bench worksheet.

Choose a real measurement floor

Use DC coupling, probe factors of 10× and the same 20 MHz bandwidth limit on both scope channels. Start around 1 V/div for CH1 and 50 mV/div for CH2, with zero centered and no clipping. Use Normal acquisition for all four records. Keep the vertical settings and probe locations unchanged through the sequence.

Choose the analyzer’s --floor-v from the actual measurement setup. It must be at least the voltage increment visible in the retained SENSE data and a conservative allowance for observed shorted-input noise at that same scale. Check the SENSE probe with its tip at G0 before and after the sequence. Record its mean, root mean square (RMS) noise and peak-to-peak excursion, then return the tip to its original SENSE pad.

At a displayed 50 mV/div over an eight-division vertical span, an ideal 12-bit conversion step would be about 0.098 mV. This supplies a minimum scale check, while the actual export and noise determine the usable floor. The example command uses 0.1 mV, or 0.0001 V. Raise it when the observed voltage step or input noise is larger. At 100 mV/div, even the ideal conversion step is about 0.195 mV, so 0.1 mV would already be too small.

Inspect the active floating trace, which spans many voltage levels, to establish the retained CSV increment. Preserve all available digits during normalization. A grounded file containing only zeros provides no proof of 0.1 mV resolution. If a trace clips, restart the complete four-record sequence at a suitable fixed scale and choose its corresponding floor. The supported floor range is 0.05–1 mV. A setup requiring a larger floor remains outside this worksheet procedure.

The source-zero record measures background with the actual receiver, resistor, probe and geometry. The analyzer adds that background allowance to the selected floor. The comparison assumes background conditions remain comparable during the subsequent captures. Keep nearby equipment, hands and cable positions stable.

Preserve paired native samples

With only CH1 and CH2 enabled, select 10 kpts memory depth, meaning ten thousand stored sample points. Start near 100 µs/div, where a microsecond (µs) is 10⁻⁶ second. Use CH1 rising-edge triggering for the active source records. Their native captures must contain 6–18 complete source cycles, each with period 98–102 µs. Maximum sample spacing must be no more than 0.5% of the measured period, about 0.5 µs at 10 kHz.

Save each simultaneous two-channel acquisition through Storage, Save, Choose, Save Wave, using Data Source Memory and file type CSV. Each CSV stores text fields for each timestamp. Preserve the original instrument exports. Normalize copies to exactly time_s,drive_v,sense_v, using seconds and probe-scaled volts.

Keep both channel values on their original time rows and preserve every row of one contiguous segment. A documented fixed time-origin subtraction is allowed. Keep absolute normalized timestamps within ±1 s. The program accepts 1000–20000 rows and at most 2 MB per file. Record the native sample interval, vertical scales and chosen floor alongside each file.

The four records must be separate acquisitions. The program rejects identical parsed arrays, while the raw exports and operator notes establish provenance. A phasor represents a signal’s amplitude and phase at one frequency. The program uses nonnegative background allowances without subtracting blank phasors from unrelated active waveforms. The source-zero record can start at an arbitrary phase and uses the active record’s fitted frequency only as the analysis frequency.

Compare screened transfer levels

The code finds rising source-midpoint crossings in each active capture and trims to complete cycles. It uses a least-squares sine fit with an offset term for DRIVE and SENSE, minimizing the sum of squared sample differences. Residuals are the remaining differences between samples and the fitted waveform. Phase is defined as SENSE phase minus DRIVE phase, so a positive angle means SENSE leads DRIVE. These fits use the retained sample pairs without inserting replacement interior samples.

Let A be fitted SENSE peak amplitude, r its RMS fit residual and D fitted DRIVE peak amplitude. The declared floor is F. Subscript b denotes the source-zero background. The worksheet constructs the following screening levels.

B = Ab + 3rb + F
Hfloating,lower = (Af − 3rf − B) / Df
Hgrounded,upper = (Ag + 3rg + B) / Dg
R = Hgrounded,upper / Hfloating,lower

The three-residual terms are chosen engineering allowances for this worksheet, with no statistical confidence level assigned. A finite positive floor keeps an all-zero grounded capture from producing an infinite numerical reduction. Accept R ≤0.15 only after both floating captures and the source controls pass. This corresponds to a conditional reduction of at least 16.48 dB under these screens.

The source sine must remain 3.8–4.2 Vpp with DC component within ±20 mV and RMS residual no more than 2.5% of its peak. Sense DC must remain within ±5 mV. Floating transfer must be 0.005–0.15, with phase +5° through +85° and residual no more than 5% of its peak. Its lower screening transfer must be at least 0.003.

Across the active records, frequency must remain within 0.5% and source amplitude within 2% of the initial values. The restored floating transfer must return within 10% in magnitude and 5° in phase. The blank requires source AC RMS no more than 5 mV, SENSE AC RMS no more than 0.5 mV and peak departure from its mean no more than 3 mV.

These checks can reject a fixture with excessive background, changed geometry, a loose ground link or insufficient resolution. A valid comparison establishes this fixture’s measured change at 10 kHz. The model does not assign an intrinsic shielding rating to the foil material.

Run the complete analyzer

Use Python 3.10 or newer. The experiment archive includes the analyzer, actual command-line tests, blank worksheet, circuit contract, original diagram and four constructed example captures. Replace the example floor with the documented value from your own fixed scale and receiver noise.

python3 foil_pickup.py blank.csv floating.csv grounded.csv restore.csv --floor-v 0.0001
python3 -m unittest -v test_foil_pickup.py
python3 foil_pickup.py synthetic/blank.csv synthetic/floating.csv synthetic/grounded.csv synthetic/restore.csv --floor-v 0.0001

Exit 0 qualifies all entered records and their controls. Exit 1 reports an unresolved waveform or comparison. Exit 2 reports malformed input or unsupported command settings. The constructed example should report a floating transfer near 0.039, grounded transfer near 0.0009 and a conditional reduction around 31.4 dB after its declared allowances.

"""Compare capacitive pickup with a floating and grounded planar foil screen."""
import argparse
import csv
import hashlib
import math
from pathlib import Path

ROUNDING = 1e-9


class BadInput(ValueError):
    pass


class Unresolved(ValueError):
    pass


def bound(value, low, high, label):
    if not low-ROUNDING <= value <= high+ROUNDING:
        raise Unresolved(f'{label}: {value:.7g}, expected {low:g}–{high:g}')
    return value


def read_capture(path):
    try:
        if path.stat().st_size > 2000000:
            raise BadInput('capture exceeds 2 MB')
        with path.open(encoding='utf-8-sig', newline='') as handle:
            reader = csv.reader(handle, strict=True)
            if next(reader, []) != ['time_s', 'drive_v', 'sense_v']:
                raise BadInput('header must be time_s,drive_v,sense_v')
            rows = []
            for row in reader:
                if len(rows) >= 20000 or len(row) != 3:
                    raise BadInput('too many rows or wrong column count')
                values = tuple(float(v) for v in row)
                if not all(map(math.isfinite, values)):
                    raise BadInput('samples must be finite')
                rows.append(values)
    except (OSError, UnicodeError, csv.Error, ValueError) as error:
        raise BadInput(str(error)) from error
    if len(rows) < 1000:
        raise BadInput('need at least 1000 native sample rows')
    if any(b[0] <= a[0] for a, b in zip(rows, rows[1:])):
        raise BadInput('timestamps must increase strictly')
    for t, drive, sense in rows:
        bound(abs(t), 0, 1, 'absolute time (s)')
        bound(abs(drive), 0, 2.3, 'raw drive (V)')
        bound(abs(sense), 0, .5, 'raw sense voltage (V)')
    return rows, hashlib.sha256(repr(rows).encode()).hexdigest()


def fit(rows, column, frequency):
    basis = [(1, math.sin(2*math.pi*frequency*(t-rows[0][0])),
              math.cos(2*math.pi*frequency*(t-rows[0][0]))) for t, _, _ in rows]
    matrix = [[sum(r[a]*r[b] for r in basis) for b in range(3)] for a in range(3)]
    rhs = [sum(r[a]*sample[column] for r, sample in zip(basis, rows)) for a in range(3)]
    work = [row+[value] for row, value in zip(matrix, rhs)]
    for column_index in range(3):
        pivot = max(range(column_index, 3), key=lambda n: abs(work[n][column_index]))
        work[column_index], work[pivot] = work[pivot], work[column_index]
        if abs(work[column_index][column_index]) < 1e-12:
            raise Unresolved('sine fit is singular')
        divisor = work[column_index][column_index]
        work[column_index] = [v/divisor for v in work[column_index]]
        for index in range(3):
            if index != column_index:
                factor = work[index][column_index]
                work[index] = [a-factor*b for a, b in zip(work[index], work[column_index])]
    offset, sine, cosine = (row[-1] for row in work)
    amplitude = math.hypot(sine, cosine)
    residual = math.sqrt(sum((sample[column]-sum(a*b for a, b in zip(r, (offset, sine, cosine))))**2
                             for r, sample in zip(basis, rows))/len(rows))
    return dict(offset=offset, amplitude=amplitude, phase=math.atan2(cosine, sine), residual=residual)


def sample_checks(rows, frequency):
    duration = rows[-1][0]-rows[0][0]
    bound(duration*frequency, 6, 25, 'record duration in source cycles')
    gap = max(b[0]-a[0] for a, b in zip(rows, rows[1:]))
    bound(gap*frequency, 0, .005, 'maximum sample gap / period')


def active(rows):
    midpoint = (max(r[1] for r in rows)+min(r[1] for r in rows))/2
    if any(a[1] == midpoint == b[1] for a, b in zip(rows, rows[1:])):
        raise Unresolved('source has a repeated midpoint plateau')
    edges = []
    for a, b in zip(rows, rows[1:]):
        if a[1] < midpoint <= b[1]:
            edge = a[0]+(midpoint-a[1])*(b[0]-a[0])/(b[1]-a[1])
            edges.append((edge, *(a[k]+(edge-a[0])*(b[k]-a[k])/(b[0]-a[0]) for k in (1, 2))))
    if not 7 <= len(edges) <= 19:
        raise Unresolved('need 6–18 complete rising-midpoint source cycles')
    for a, b in zip(edges, edges[1:]):
        if not 98e-6-1e-12 <= b[0]-a[0] <= 102e-6+1e-12:
            raise Unresolved('source period must be 98–102 us')
    frequency = (len(edges)-1)/(edges[-1][0]-edges[0][0])
    sample_checks(rows, frequency)
    selected = [edges[0], *(r for r in rows if edges[0][0] < r[0] < edges[-1][0]), edges[-1]]
    source, sense = fit(selected, 1, frequency), fit(selected, 2, frequency)
    bound(2*source['amplitude'], 3.8, 4.2, 'actual drive amplitude (Vpp)')
    bound(source['offset'], -.020, .020, 'drive DC component (V)')
    bound(source['residual']/source['amplitude'], 0, .025, 'drive sine residual / peak')
    bound(sense['offset'], -.005, .005, 'sense DC component (V)')
    phase = math.degrees(math.atan2(math.sin(sense['phase']-source['phase']),
                                  math.cos(sense['phase']-source['phase'])))
    return dict(frequency=frequency, source=source, sense=sense, phase=phase,
                gain=sense['amplitude']/source['amplitude'])


def blank_level(rows, frequency, floor):
    sample_checks(rows, frequency)
    source, sense = fit(rows, 1, frequency), fit(rows, 2, frequency)
    bound(source['offset'], -.010, .010, 'zero-source DC (V)')
    bound(math.hypot(source['amplitude']/math.sqrt(2), source['residual']), 0, .005, 'zero-source AC RMS (V)')
    bound(sense['offset'], -.002, .002, 'blank sense mean (V)')
    bound(math.hypot(sense['amplitude']/math.sqrt(2), sense['residual']), 0, .0005, 'blank sense AC RMS (V)')
    bound(max(abs(r[2]-sense['offset']) for r in rows), 0, .003, 'blank peak departure (V)')
    return sense['amplitude']+3*sense['residual']+floor


def floating_checks(result, background):
    sense, source = result['sense'], result['source']
    bound(result['gain'], .005, .15, 'floating transfer magnitude')
    bound(result['phase'], 5, 85, 'sense minus drive phase (deg)')
    bound(sense['residual']/sense['amplitude'], 0, .05, 'floating residual / peak')
    lower = (sense['amplitude']-3*sense['residual']-background)/source['amplitude']
    bound(lower, .003, .15, 'floating lower transfer screen')
    return lower


def main():
    parser = argparse.ArgumentParser(description=__doc__)
    for name in ('blank', 'floating', 'grounded', 'restore'):
        parser.add_argument(name, type=Path)
    parser.add_argument('--floor-v', type=float, default=.0001,
                        help='declared voltage resolution floor, 0.00005–0.001 V')
    args = parser.parse_args()
    if not math.isfinite(args.floor_v) or not .00005 <= args.floor_v <= .001:
        parser.error('floor-v must be 0.00005–0.001 V')
    try:
        captures = [read_capture(p) for p in (args.blank, args.floating, args.grounded, args.restore)]
        if len({signature for _, signature in captures}) != 4:
            raise BadInput('captures contain identical parsed sample arrays')
        results = [active(rows) for rows, _ in captures[1:]]
        first, grounded, final = results
        background = blank_level(captures[0][0], first['frequency'], args.floor_v)
        lower = floating_checks(first, background)
        floating_checks(final, background)
        for result in results[1:]:
            bound(result['frequency']/first['frequency'], .995, 1.005, 'source frequency ratio')
            bound(result['source']['amplitude']/first['source']['amplitude'], .98, 1.02, 'source amplitude ratio')
        bound(abs(final['gain']/first['gain']-1), 0, .10, 'restored relative transfer change')
        phase_change = math.degrees(math.atan2(math.sin(math.radians(final['phase']-first['phase'])),
                                             math.cos(math.radians(final['phase']-first['phase']))))
        bound(abs(phase_change), 0, 5, 'restored transfer phase change (deg)')
        upper = (grounded['sense']['amplitude']+3*grounded['sense']['residual']+background)/grounded['source']['amplitude']
        ratio = upper/lower
        bound(ratio, 0, .15, 'grounded upper / floating lower transfer')
    except BadInput as error:
        parser.exit(2, f'INPUT: {error}\n')
    except Unresolved as error:
        parser.exit(1, f'UNRESOLVED: {error}\n')
    print(f"floating: gain={first['gain']:.6f}, phase={first['phase']:.2f} deg, lower screen={lower:.6f}")
    print(f"grounded: gain={grounded['gain']:.6f}, upper screen={upper:.6f}")
    print(f"restore: gain={final['gain']:.6f}, phase={final['phase']:.2f} deg")
    print(f"background allowance={background*1000:.3f} mV; conditional reduction at least {-20*math.log10(ratio):.2f} dB")
    print('PASS: grounding the fixed foil screen reduces the screened pickup level, with the floating transfer restored.')
    return 0


if __name__ == '__main__':
    raise SystemExit(main())

Exercise a failed comparison

Replace the synthetic grounded file with a fresh floating-network trace at a different time origin. The program should reject the claimed reduction. Add a strong unrelated sine to the grounded receiver instead, and its residual allowance should also prevent a false qualification. The host tests include these cases alongside source changes, failed restoration, reversed SENSE polarity, gaps, duplicate arrays and malformed values.

A dedicated host case uses exact zero blank and grounded samples with a positive declared floor. It checks finite numerical behavior. The instrument-resolution decision remains an operator measurement recorded in the worksheet. All supplied traces are constructed network data, and physical observations remain blank.

Challenge — halve the source amplitude

For the same linear capacitive network, what happens when actual DRIVE changes from 4 Vpp to 2 Vpp?

Answer. The induced voltage amplitudes halve, while the ideal transfer magnitudes and their ratio remain unchanged. Fixed receiver noise and the declared voltage floor do not halve, so the conditional reduction screen can worsen or become unresolved. The supplied analyzer’s 3.8–4.2 Vpp source gate belongs to the original experiment.

The air-core coil pickup experiment varies magnetic coupling through position and rotation. The shared-return experiment follows conducted reference-voltage error. This foil fixture gives capacitive coupling its own controlled measurement and return path.

Primary references