LTC6992-1: Change the Pulse Width Without Retuning the Clock

Before connecting any input or output cables, connect the DHO804’s rear Ground Terminal to earth ground with the supplied ground cable, following the DHO800 User Guide. Its Type-C power input does not ground the instrument through the power cord. Use the supplied DHO804 power adapter and keep the SPD3303X’s protective earth connected. The probe grounds and signal return do not replace the DHO804’s required earth lead.

This is the short-wiring 3.30 V fixture for the ADI LTC6992IS6-1#TRMPBF
S6 package. Open preview.html for the circuit and measurement procedure.
The original editable diagram is fixture.svg, with fixture.png for viewing.
Keep the MOD source at zero or disabled until the chip supply is present.

Copy sweep-blank.csv. Fill the two voltage cells per step using measured
V+ and MOD. Export each stopped, settled scope capture from memory.
Keep the original files. Copy time in seconds and OUT in volts into files
using the trace-blank.csv header. Name the six files low.csv, quarter.csv,
middle.csv, three_quarters.csv, high.csv and middle_repeat.csv. Put them
beside the filled worksheet. Run with Python 3 and its standard library.

    python3 pwm_sweep.py sweep-filled.csv
    python3 -m unittest -v test_pwm_sweep

Exit 0 means all comparison screens passed, exit 3 means a capture set did
not meet a screen and exit 2 means input could not be read or validated.
Static classifications apply to captured samples. A scope can miss activity
outside the window or between samples. No physical measurements are supplied.