- GPS Data: Validate Checksums, Fix State and Observation Age
Receive documented GPS messages, validate their checksum and fix fields, pair matching epochs and expire repeated or silent observations without displaying stale coordinates. - ST7789 Display: Draw Partial Windows and Measure the Byte Budget
Calculate and test exact rectangle transfers to a documented ST7789 module, qualify the panel corners and separate bus duration from optical refresh. - LSM6DSOX Gyro: Calibrate Bias and Track a Bounded Turn
Estimate a stationary gyro bias, integrate a short single-axis turn with real observation intervals and invalidate the result when sampling gaps break the experiment. - TSOP38238: The Output Shows Infrared Bursts, Not a 38 kHz Clock
Build a filtered 3.3 V TSOP38238 receiver and capture infrared envelopes with bounded buffers, strict NEC32 checks and limited repeat association. - AO3400A: A Low-Side Switch Must Have the Right Return Path
Build a small AO3400A low-side module and trace its load return, gate divider, finite PWM stop and the limits of a static loss calculation. - MAX31855K: A Plausible Temperature Frame Can Still Have the Wrong Cold Junction
Build a 3.3 V MAX31855K module, decode the full signed frame and separate wiring faults from a cold-junction temperature mismatch. - PAM8302A Amplifier Module: Both Speaker Terminals Are Driven
A low-gain PAM8302AADCR speaker module makes both driven outputs explicit. Calculate input filtering and ideal audio power without confusing raw switching RMS with sound. - MCP73831 Charger Module: Charge Status Is Not a System Power Path
Build a 100 mA MCP73831-2AC charger candidate and calculate why an attached system load changes the current seen by charge termination. - DRV8833 Motor Module: Coast, Brake and Current Regulation Are Different
A deliberately modest DRV8833 module separates PWM commands, winding-current trip and motor motion. Full Pico code includes coast reversal delay and a latched fault path. - LUMA Music: Jingle Bells and Three Independent Colour Groups
Play Jingle Bells on an ESP32-C3 passive piezo with six LEDs in three independent colour pairs. Rev C includes a complete schematic, code and English simulation. - Play Jingle Bells with a DFPlayer Mini, Pico and Six Tree Lights
Play an original synthesized Jingle Bells MP3 through a DFPlayer Mini and speaker, with a Pico-controlled six-LED animation. Includes schematics, code and prototype limits. - Replacing a File: Visible Now Is Not Proven Durable
Run real isolated file replacements and process exits, then separate atomic pathname visibility, returned synchronization calls and untested physical power-loss durability. - E-Paper Keeps Pixels After the Program Stops
Run one bounded full refresh on a Waveshare V4 e-paper HAT, trace BUSY and pin ownership, and keep persistent pixels separate from a live sensor state. - Camera Module 3: A Frame Timestamp Is Not One Exposure Instant
Capture Camera Module 3 images and metadata from one request, then separate first-pixel timestamps, exposure windows and unknown rolling-row timing. - LM331: A Pulse Count Can Encode an Analog Voltage
Trace a complete LM331 charge-balance circuit, derive its nominal voltage-to-frequency equation and test how finite counting windows and analog errors limit the result. - Digital Microphone: A Quiet Average Can Hide Clipped Peaks
Trace an SPH0645 microphone’s power and I2S format, decode signed samples, and compare peak, RMS and known digital clipping without claiming acoustic calibration. - Multiroom Door Alerts: A PUBACK Is Not the Other Room’s Acknowledgement
Run a loopback MQTT experiment that separates broker PUBACK from a correlated application receipt, then test late replies, duplicate IDs and receiver restart. - CD4046B: Following a Frequency Is Different from Acquiring Lock
Build a CD4046BE loop and compare acquisition with tracking. Keep comparator choice, filter memory, phase evidence and nominal RC arithmetic separate. - SCD41: Pressure Compensation Is a Separate Input, Not a CO₂ Calibration
Feed measured BMP390 pressure into SCD41, verify100Pa command units and readback, and reject stale updates without confusing compensation with CO₂ calibration. - Pot Drainage: Weigh the Water That Leaves Before Calling It Dry-Back
Weigh a pot and its drainage collector on independent HX711 platforms. Use separate calibration and observed read windows to distinguish compatible transfer from unknown loss.

Build a radio
Soldering required. Check the supplied parts and board revision.