Two-bit decoder and one-hot output
Turn an address into one chosen line
A decoder turns a binary input code into a chosen output line. One-hot means exactly one line is 1 when enabled. Enable is the control that allows these outputs to operate.
EXPERIMENT BENCH
Change the circuit settings, predict the readings, then check a challenge. These are learning models, with the assumptions explained in each lesson.
Sign in to save progress. Guest progress stays on this device.
Why it works
Ideal binary logic: 0 means low and 1 means high, not a measured voltage. Supply behavior, current, output loading and response delay are omitted; diagrams show functions, not chip pinouts. Here enable E = 1 activates high outputs; E = 0 disables them. The active-line index −1 means none, not negative voltage.
b0 and b1 are input bits; code n = b0 + 2b1 ranges from zero to three. E is enable. With E = 1 only line Qn is high; with E = 0 all four outputs are low.
Difficulty
Build · Build it
Power on with b0 = 0, b1 = 1 and E = 1. Choose code 2 and make line Q2 active.
Need a hint?
b0 = 0; b1 = 1; E = 1 → Q2 = 1
Explore · Change the inputs
Set b0 = 1, b1 = 1 and E = 1. Choose code 3 and make line Q3 active.
Need a hint?
b0 = 1; b1 = 1; E = 1 → Q3 = 1
Solve it · Solve the challenge
Keep b0 = 1 and b1 = 1; set E = 0. Disable every output.
Need a hint?
b0 = 1; b1 = 1; E = 0 → Q0 = Q1 = Q2 = Q3 = 0
Extra reading and circuit recipes
Turn an address into one chosen line
Two switches can choose one of four destinations. The decoder expands a compact address into a visible choice of line.
n = b0 + 2b1; E = 1 → Qn = 1; E = 0 → Q0 = Q1 = Q2 = Q3 = 0
The binary code describes which line to choose; enable says whether to make that choice active. These are independent controls.
A useful pattern
Only two address bits choose four lines: every extra binary address bit doubles the possible choices.
Beyond the model
Disabled outputs are all zero, so the disabled state is not one-hot. The input code can still be three while no output is active.
A useful trap to avoid
Line number 2 does not mean two active lines. The number identifies a destination; the active-output count remains one when enabled.
Code stays at 3, but E changes from 1 to 0. Which line is high?
- Q3
- none
- all four
Read more
Enable controls whether the decoded choice is allowed to appear. Disabling forces every output low.
Build it
Set b0 = 0, b1 = 1, E = 1. The weighted code is 2 and only Q2 is high.
n = 2; Q2 = 1
Change the inputs
Set b0 = 1, b1 = 1, E = 0. Code is 3, but every output remains low.
Q0 = Q1 = Q2 = Q3 = 0
Try another path
With enable on, visit codes zero through three and count the active lines each time. Then repeat with enable off.