The label says 3.3 V. The meter says less. Before replacing the regulator, find out where the voltage disappeared. A weak source, insufficient regulator headroom and a thermal problem can produce similar symptoms, but they ask for different measurements. Build a small resistor load, deliberately add a little source resistance, then lower the input voltage while recording both sides of an AMS1117.
Three questions beat one voltage reading
A linear voltage regulator adjusts an internal conducting element to hold an output voltage; the unused electrical power becomes heat. LDO means low-dropout regulator, a linear regulator designed to work with a relatively small difference between input and output. “Low” does not mean zero. This article uses the Advanced Monolithic Systems AMS1117-3.3, fixed-output SOT-223 version. A marking on an unidentified module does not establish the same manufacturer or electrical behavior.
Droop is a fall in voltage as load increases. A load is whatever draws power from the supply; here it consists only of resistors. Headroom is the voltage difference measured directly between the regulator’s input and output nodes. Dropout is the operating region where there is too little headroom to maintain the intended regulation. A thermal fault involves excessive internal temperature. These are not mutually exclusive: source-path droop can push a regulator into dropout.
Measure VS at the source’s positive connection, VIN at the regulator input and VOUT at its output, all relative to the same local ground. VIN means input voltage; VOUT means output voltage; GND, ground, is the shared zero-volt reference. If VS stays steady while VIN falls, investigate the path between them. If VIN approaches VOUT during a controlled input sweep, investigate headroom. If a problem develops over time, stop and examine power loss and thermal construction; timing alone does not prove overheating.
Choose a reproducible, modest load
| Reference | Exact part or requirement | Purpose |
|---|---|---|
| U1 | Advanced Monolithic Systems AMS1117-3.3, SOT-223, on an already soldered passive adapter with the output tab on a copper pad | The fixed 3.3 V regulator under investigation; not the adjustable AMS1117. |
| C1, C2 | Two KEMET T491D476K016AT: 47 µF, ±10%, 16 V, standard solid manganese-dioxide tantalum, case D; soldered to passive adapters | C1 spans local VIN–GND; C2 spans VOUT–GND. Both have polarity. |
| C3 | 100 nF ceramic, rated at least 10 V | Short local VIN-to-GND bypass path, directly beside U1. |
| R0 | 330 Ω, ±1%, 1 W axial resistor | Always-connected output load, about 10 mA at 3.3 V. |
| R1, R2 | 100 Ω and 47 Ω, ±1%, 1 W axial resistors; Vishay PR01 is a suitable specified series | Choose one added load: about 33 mA or 70 mA. |
| S1 | Break-before-make SPDT center-off toggle, rated for at least 0.2 A at 5 V DC | Select R1, neither, or R2. Never connect both added loads. |
| RS, JP1 | 2.2 Ω, ±1%, 1 W resistor, with a removable shorting jumper across it | Known source-path resistance; fit or remove JP1 only with power off. |
| R3 | 10 kΩ, ±1%, at least 0.25 W | Local input bleeder: discharges C1 after the source is disconnected. |
| Source | Isolated adjustable regulated bench supply, 0–5.1 V, current limit set to 120 mA | Allows controlled voltage changes. No mains wiring, battery pack or board USB supply is part of this experiment. |
| Measurement | Digital multimeter, insulated probes, short wires and a breadboard; two meters are helpful | Measure steady voltages and actual resistor values without putting the meter in current mode. |
SPDT means single-pole double-throw: one common contact selects one of two contacts. Center-off adds a disconnected middle position. Break-before-make means the old contact opens before the new one closes. DC means direct current, with a fixed polarity in this experiment. A milliampere, mA, is one thousandth of an ampere; µF means microfarad and nF means nanofarad, units of capacitance. SOT-223 is the manufacturer’s surface-mount package designation, not a breadboard pin order.
A resistor opposes current; its resistance is measured in ohms, Ω. A tolerance such as ±1% gives the permitted initial variation around its marked value. A bypass capacitor supplies or absorbs fast local changes in charge. Current limiting makes the source reduce its output voltage when demand exceeds the selected limit; it is a safeguard, not normal regulation. Capacitor polarity is the required positive/negative orientation.
The adapters must contain no regulator, indicator or other hidden load. Before power is connected, use continuity mode to identify U1’s numbered leads, its output tab and each adapter terminal. View the marked package from above with its three leads toward you: pin 1 is GND, pin 2 is VOUT, and pin 3 is VIN; the large tab is also output. The adapter’s convenient left-to-right labels can differ. Keep the tab away from ground clips and other conductors. Obtain a prepared adapter if soldering these parts is outside your present skill level.
Solderless breadboards for the prepared passive adapters and resistor fixture. Keep the isolated source current limit at 120 mA.
A solderless breadboard holds parts with spring contacts, without soldering. Use the already assembled passive adapters described above and keep the source current limit at 120 mA. One board is enough for this fixture. Check the contact groups with all power disconnected before wiring.
Temu affiliate offer · Product idea
Optional electronics starter-kit advertisement
Electronics component starter kit with a breadboard, jumper wires and assorted parts. Arduino controller board not included.

Product idea only, not a verified experiment parts list. Use the exact hardware and wiring specified in the article; this kit is not a confirmed substitute. Tricky Circuit has not bench-tested this kit.
Some links below are Temu affiliate links. Tricky Circuit may earn a commission if you buy through them.
The output capacitor is a circuit component, not decoration
The reviewed AMS manufacturer document, carrying the date 14 September 2012, specifies an output capacitor for compensation and describes 22 µF solid tantalum as covering its stated operating cases. We choose a nominal 47 µF solid tantalum part, above that reference value. C2 is fitted throughout; do not remove it to provoke a fault. Compensation keeps the regulator’s correcting action from repeatedly overshooting itself.
ESR means equivalent series resistance, the effective resistive loss of a capacitor at a specified frequency. The current KEMET T491 table lists 0.8 Ω maximum at 100 kHz and 25 °C for this 47 µF, 16 V case-D part. That is a component specification, not a universal acceptable ESR range for all AMS1117-branded devices. The reviewed AMS document does not give a numerical ESR stability window. Do not invent one, or assume an arbitrary ceramic capacitor is an interchangeable output part. A different manufacturer’s regulator requires that manufacturer’s instructions.
On these tantalum capacitors the marked stripe identifies the positive terminal. Connect C1 positive to VIN and C2 positive to VOUT; both negative terminals go to local GND. This differs from the negative stripe commonly found on aluminum electrolytic capacitors. The 16 V rating provides ample voltage margin for the 5.1 V project ceiling and follows KEMET’s room-temperature derating guidance. Install the capacitors close to their nodes, with short returns. Do not connect another powered source to VOUT, or deliberately short the charged input to ground.
Wire three measurement points and a selectable load

| Node or lead | Connections |
|---|---|
| VS | Source positive → RS upper-path end. JP1 connects across both ends of RS when fitted. |
| VIN | RS other end → U1 pin 3, C1 positive, C3 first end and R3 first end. |
| VOUT | U1 pin 2 and output tab → C2 positive, R0 upper end and S1 common contact. |
| Selected branch | S1 first throw → R1 upper end; S1 second throw → R2 upper end. Center-off joins neither. |
| Local GND | U1 pin 1; C1/C2 negatives; C3 other end; R0/R1/R2 lower ends; R3 other end; source negative. |
| Meter | Black lead stays at local GND. Red lead visits VS, VIN or VOUT in voltage mode. Probe clips must not bridge adjacent pins. |
The fixture deliberately adds resistance only to the positive supply path. Keep the negative return short. If investigating a real source, also measure across its own positive and negative terminals in a separate, clearly labeled measurement: a weak return can change voltages referenced to local ground. Do not silently change the black-lead reference between columns.
The input bleeder R3 also consumes current. At 5 V its current is 0.5 mA, which travels through RS but not through U1’s output. Ground current is the current U1 uses internally and returns through its ground lead. It also passes through RS. Ignoring these paths underestimates the input drop and the regulator loss.
Predict current and heat before switching on
For a resistor, Ohm’s law gives current I = V/R. Electrical power is P = VI, or V²/R for a resistor. R0 remains in parallel with the selected branch, so their currents add. The following table assumes exactly 3.300 V and nominal resistance values; it is not a set of measured outputs.
| S1 position | Total output current | Added resistor power | Estimated U1 loss at local VIN = 5 V |
|---|---|---|---|
| Center / baseline | 10.00 mA | None; R0 itself dissipates 0.033 W | 0.077 W |
| R1 / medium | 43.00 mA | 0.1089 W in 100 Ω | 0.1331 W |
| R2 / high | 80.21 mA | 0.2317 W in 47 Ω | 0.1964 W |
The loss column deliberately assumes 12 mA of U1 ground current. It is a conservative worksheet assumption for this small fixture, not a guaranteed bound under every input and load condition. Here PIC means power lost inside the integrated circuit (IC), the packaged regulator. Iload is its output load current and Iground its assumed internal ground current. The calculation is:
Iload = VOUT/330 + VOUT/Rselected (omit the second term at center-off)
PIC ≈ (VIN − VOUT) × Iload + VIN × Iground
High-load example: (5 − 3.3) × 0.080213 + 5 × 0.012 ≈ 0.1964 W
A resistor marked 1 W does not automatically stay cool to touch. Keep the resistor bodies separated from plastic and adjacent components, and let them cool with power disconnected before handling. For the chosen 3.2–3.4 V output screen and ±1% resistor corners, the largest calculated selected-resistor power is about 0.249 W. The worksheet’s largest source current is about 96.0 mA with its stated ground-current assumption, below the 120 mA source limit. That margin does not validate a shorted, miswired or substituted circuit.
First obtain a believable baseline
- Disconnect the supply. Check resistor values in isolation and record them. Verify capacitor polarity, lead mapping and the common ground. Set S1 to center-off and fit JP1 across RS.
- Set the source to 5.00 V and the current limit to 120 mA before connecting the fixture. A brief charging transient is possible; if the source remains in current limit after one second, switch off and investigate.
- Measure VS, VIN and VOUT. With the jumper fitted, VS and VIN should differ only by real wire/contact losses. The expected target is near 3.3 V, not an exact universal 3.300 V.
- Use 3.2–3.4 V as a project screening window. If the baseline lies outside it, stop before adding load. This window is a troubleshooting choice, not a replacement for the datasheet’s accuracy conditions.
- Select R1 for at most five seconds, record all three voltages, then return to center-off. Repeat with R2 for at most five seconds. Allow at least 30 seconds powered off between load trials. Stop immediately for unexpected current, unstable output or signs of heating; do not use a finger as a temperature probe.
If using one meter, repeat the same short trial for each node after the cooling interval; label the readings as sequential, not simultaneous. A digital multimeter, abbreviated DMM, generally averages what it sees. It can miss short supply dips or fast oscillation—an unwanted repeating change caused, for example, by an unstable control loop. A steady displayed number does not prove a quiet voltage waveform. This fixture measures slow behavior, not the transient supply demand of a radio or motor.
Test A: make the source path visible
Power off, disconnect the source and wait until both VIN and VOUT measure below 0.1 V. Remove JP1 so that RS = 2.2 Ω is in the input path. Restore 5.00 V and repeat only the baseline and R1 medium-load trials, each within the five-second limit. Do not start by using R2 with this added resistance: it spends more of the headroom and confuses the first comparison.
At medium load, using the assumed 12 mA ground current and the input bleeder, the nominal worksheet gives source current about 55.49 mA, a path drop of 0.1221 V, local VIN about 4.8779 V, and headroom about 1.5779 V if VOUT remains 3.3 V. The source can still display 5 V while the regulator receives less. Record the real result; the arithmetic does not guarantee maintained regulation.
Use the measured difference VS−VIN to find the missing voltage. A larger difference than predicted points toward additional resistance, an unexpected current path or a measurement error. Check contacts and ground connections with power off. If VOUT also falls, source-path loss and dropout may both be present. Calling either symptom “bad AMS1117” skips the actual diagnosis.
Test B: find a practical headroom boundary
Power off, wait for both rails below 0.1 V and refit JP1. Use R1, not R2. First confirm the normal 5 V result. Then lower the source in 0.1 V steps, recording actual VIN and VOUT during a fresh trial of no more than five seconds at each step; power off for at least 30 seconds between trials. Stop on the first clear output fall, on unexpected current or unstable output, or when the source reaches 3.4 V. Never raise the source above 5.1 V.
For this exercise, call a repeatable output reduction of more than 2% from the same unit’s 5 V baseline a practical loss-of-regulation threshold. For a 3.300 V baseline, 2% is 0.066 V, giving 3.234 V. Repeat around the boundary only if the meter’s specified error and displayed resolution are small enough to distinguish that change. Otherwise report an interval and the measurement limitation. This is our observational definition; it is not the manufacturer’s specified dropout test.
Calculate VIN−VOUT from each pair. Do not subtract an assumed 3.3 V after the output has fallen. Restore 5 V for a final short confirmation trial. A quick, repeatable recovery with adequate input supports a headroom explanation; it does not exclude capacitor, stability or connection faults. There is no single magic input voltage that guarantees every AMS1117 sample, vendor, temperature and load. The calculator therefore never manufactures an output-voltage curve from a constant dropout guess.
Test C is a power check, not a burn-in test

Thermal shutdown is a protective interruption of operation at excessive internal temperature. It is not a desired operating mode. Junction temperature is the temperature inside the semiconductor die. It is not the same as the plastic package surface temperature. Thermal resistance describes temperature rise per watt along a heat-flow path. The approximate steady-state relation ΔT = P × θ uses a particular thermal resistance θ, expressed in °C/W. Changing copper area, airflow, mounting or nearby heat changes that path.
For illustration only, 0.1964 W multiplied by an assumed 95 °C/W gives about 18.7 °C rise; assuming 150 °C/W gives about 29.5 °C. Those are two thermal scenarios, not temperature predictions for an unspecified breadboard adapter. They are also not the rise after a five-second test. The small fixture intentionally stays far below the high-current claims often printed on modules, and it does not demonstrate a thermal-shutdown cycle.
If an existing design works cold but later sags or cycles while the measured local input remains steady, switch off. A thermal explanation becomes a hypothesis worth checking alongside oscillation, intermittent connections and the source’s protection mode. Review measured load current, regulator loss, the board’s copper and the exact device limits. Confirmation requires appropriate temperature measurements and time-resolved electrical measurements. Do not raise voltage, add loads, cover the regulator or defeat protection to make the failure more dramatic.
Use the complete optional worksheet
The program below runs on a computer with Python 3 and its standard library. CLI means command-line interface: type a command in a terminal to run it. Save the complete listing as ams1117_load_diagnosis.py, or use the prepared source file (in source ZIP). It solves the static input-path equation, includes R3 and assumed ground current, checks selected tolerance corners and prints its assumptions.
python ams1117_load_diagnosis.py --branch medium --source-ohms 2.2
python ams1117_load_diagnosis.py --branch high --source-ohms 0
python ams1117_load_diagnosis.py --branch medium --source-v 4.2
The entered output is assumed, even if you separately measured and entered it. The default 1.5 V headroom screen is an explicit worksheet choice, not a guaranteed device dropout rating. Failing that screen does not calculate the actual output. With the default assumed high load and 2.2 Ω path, headroom is about 1.496 V, just below that chosen screen—one reason the source-path exercise uses the medium load. No regulator-loop, transient or thermal model runs here.
"""Static load/path/heat arithmetic for the AMS1117 diagnostic fixture.
No regulator transfer curve, stability, startup, thermal shutdown or hardware
simulation is implemented. Assumed ground current and headroom are explicit.
"""
import argparse
import itertools
import json
import math
LOADS = {"baseline": None, "medium": 100.0, "high": 47.0}
BASE_OHMS = 330.0
BLEED_OHMS = 10000.0
def number(value, name, minimum, maximum):
value = float(value)
if not math.isfinite(value) or not minimum <= value <= maximum:
raise ValueError(f"{name} must be finite and within {minimum}..{maximum}")
return value
def budget(branch="high", source_v=5.0, output_v=3.3,
source_ohms=0.0, ground_ma=12.0, headroom_v=1.5,
base_ohms=BASE_OHMS, branch_ohms=None, bleed_ohms=BLEED_OHMS):
"""Assume the entered output voltage, then solve the upstream path.
A headroom comparison is only a screen against an entered assumption.
It does not predict the AMS1117 dropout voltage or actual output voltage.
"""
if branch not in LOADS:
raise ValueError("branch must be baseline, medium or high")
source_v = number(source_v, "source_v", 3.4, 5.1)
output_v = number(output_v, "output_v", 0.1, 3.4)
source_ohms = number(source_ohms, "source_ohms", 0.0, 2.222)
ground_a = number(ground_ma, "ground_ma", 0.0, 20.0) / 1000
headroom_v = number(headroom_v, "headroom_v", 0.0, 2.0)
base_ohms = number(base_ohms, "base_ohms", 326.7, 333.3)
bleed_ohms = number(bleed_ohms, "bleed_ohms", 9900.0, 10100.0)
rb = LOADS[branch]
if branch_ohms is not None:
if rb is None:
raise ValueError("baseline has no selected branch resistor")
rb = number(branch_ohms, "branch_ohms", rb * 0.99, rb * 1.01)
base_a = output_v / base_ohms
branch_a = 0.0 if rb is None else output_v / rb
load_a = base_a + branch_a
# Source current includes the input bleeder at LOCAL input voltage.
input_v = (source_v - source_ohms * (load_a + ground_a)) / (
1.0 + source_ohms / bleed_ohms)
if input_v < output_v:
raise ValueError("assumed output exceeds solved input; no valid power budget")
bleed_a = input_v / bleed_ohms
source_a = load_a + ground_a + bleed_a
source_drop = source_v - input_v
ic_w = (input_v - output_v) * load_a + input_v * ground_a
return {
"assumption": "Entered VOUT is assumed, not predicted or measured.",
"branch": branch,
"source_V": source_v,
"assumed_output_V": output_v,
"solved_local_input_V": input_v,
"source_path_drop_V": source_drop,
"available_headroom_V": input_v - output_v,
"entered_headroom_screen_V": headroom_v,
"meets_entered_headroom_screen": input_v - output_v >= headroom_v,
"load_A": load_a,
"source_A": source_a,
"base_resistor_W": output_v * base_a,
"selected_resistor_W": output_v * branch_a,
"input_bleeder_W": input_v * bleed_a,
"source_resistor_W": source_a ** 2 * source_ohms,
"estimated_ic_loss_W": ic_w,
"delivered_load_W": output_v * load_a,
"source_power_W": source_v * source_a,
"source_limit_A": 0.120,
"steady_budget_below_source_limit": source_a < 0.120,
"warning": "No stability, dropout curve, junction temperature or safe-current guarantee.",
}
def resistor_envelope():
"""Enumerate chosen fixture tolerance/output corners, not IC corners."""
rows = []
for branch in LOADS:
for out, base, bleed, rs in itertools.product(
(3.2, 3.4), (326.7, 333.3), (9900.0, 10100.0), (0.0, 2.222)
):
resistors = (None,) if LOADS[branch] is None else (
LOADS[branch] * 0.99, LOADS[branch] * 1.01)
for rb in resistors:
rows.append(budget(branch, 5.1, out, rs, 12.0, 1.5,
base, rb, bleed))
return {
"cases": len(rows),
"scope": "3.2/3.4 V output, +/-1% resistors, 5.1 V source, assumed 12 mA IC ground current.",
"max_load_A": max(r["load_A"] for r in rows),
"max_source_A": max(r["source_A"] for r in rows),
"max_selected_resistor_W": max(r["selected_resistor_W"] for r in rows),
"max_ic_loss_W": max(r["estimated_ic_loss_W"] for r in rows),
"all_below_120mA": all(r["source_A"] < 0.120 for r in rows),
}
def main(argv=None):
parser = argparse.ArgumentParser(description=__doc__)
parser.add_argument("--branch", choices=tuple(LOADS), default="high")
parser.add_argument("--source-v", type=float, default=5.0)
parser.add_argument("--output-v", type=float, default=3.3,
help="assumed or separately measured output; never inferred by this program")
parser.add_argument("--source-ohms", type=float, default=0.0)
parser.add_argument("--ground-ma", type=float, default=12.0,
help="explicit loss-budget assumption, not a measured current")
parser.add_argument("--headroom-v", type=float, default=1.5,
help="illustrative screen, not a guaranteed dropout specification")
args = parser.parse_args(argv)
try:
result = budget(args.branch, args.source_v, args.output_v,
args.source_ohms, args.ground_ma, args.headroom_v)
result["fixture_corners"] = resistor_envelope()
except ValueError as exc:
parser.error(str(exc))
print(json.dumps(result, indent=2, allow_nan=False))
if __name__ == "__main__":
main()
Read disagreements as evidence
| Observation | What to check next | What it does not prove |
|---|---|---|
| VS and VIN both fall when the load is selected | Source current-limit status, real source capability and the wiring; repeat a baseline after switching off and inspecting. | It does not locate the entire drop inside U1. |
| VS is steady; VS−VIN grows | Input wires, RS, contacts and return path; measure directly at U1’s ground node. | It does not exclude dropout downstream. |
| VOUT follows VIN down during the fixed-load sweep | Repeat the boundary with correct capacitors and a good baseline, then calculate measured headroom. | A DMM reading alone does not verify loop stability or a manufacturer dropout specification. |
| Output is wrong even with the baseline load | Device identity, fixed versus adjustable version, pin mapping, polarity, missing C2 and solder bridges. | It does not justify immediately applying a larger supply. |
| Output changes after a delay or cycles | Stop; evaluate loss, thermal construction, source protection and possible oscillation using suitable equipment. | Timing is not proof of overheating. |
Challenge: did the dropout get smaller?
A hypothetical learner records VIN = 4.10 V and VOUT = 2.95 V during a failed-regulation trial. They subtract 3.30 V from VIN and announce “0.80 V dropout.” What is wrong with that calculation? Which second measurement helps distinguish cable loss from a falling source?
Show the reasoning
The measured headroom is 4.10−2.95 = 1.15 V. Subtracting the desired output hides the fact that the output has already fallen. Neither number alone establishes a datasheet dropout result: a defined output-deviation criterion, load and temperature are needed. Measure VS at the source as well as local VIN and compare VS−VIN under the same load. If both drop, investigate the source; if mainly their difference grows, investigate the path. These invented readings are a reasoning exercise, not claimed measurements from this fixture.
Sources and the next useful experiment
This is a diagnostic follow-up to the site’s existing AMS1117 connection overview, not another copy of its general wiring introduction. It concentrates on paired input/output readings and a controlled resistor load. Continue with the electronics course.
- Advanced Monolithic Systems AMS1117 manufacturer datasheet, dated 14 September 2012, unchanged manufacturer PDF mirrored by LCSC: package map, output capacitor guidance and thermal dependence. The original manufacturer-hosted PDF could not be retrieved during this review; the mirror is disclosed rather than presented as a newly verified manufacturer release. Its differing summary/table headroom figures are not collapsed into a universal input threshold.
- KEMET T491 manufacturer datasheet, 8 July 2026: exact 47 µF/16 V case-D selection, component ESR test conditions, polarity and recommended voltage derating.
- Vishay PR01/PR02/PR03 manufacturer datasheet, 8 July 2025: selected resistor series, ratings and temperature derating. A resistor rating is not a touch-temperature promise.