A capacitor does not normally jump from zero to the supply voltage when it charges through a resistor. You can watch that change with a meter and a stopwatch. This experiment turns an abstract time constant into something you can measure on a breadboard.
Your goal: predict when a capacitor will reach about 3.16 volts from a 5-volt supply, then explain why the real result may differ.

What the two parts do
A capacitor stores energy in an electric field. Its capacitance, C, describes how much charge is needed for a given voltage change. A resistor limits the charging current. Together they form an RC circuit, meaning a resistor–capacitor circuit. Resistance R is measured in ohms (Ω), capacitance in farads (F), and voltage in volts (V).
Our capacitor is 470 microfarads, written 470 µF: 0.000470 F. Our resistor is 10 kilohms, written 10 kΩ: 10,000 Ω. Their product is a time: τ = R × C = 10,000 × 0.000470 = 4.7 seconds. The Greek letter τ, pronounced “tau,” is the time constant.
Parts and connections
- A regulated 5 V direct-current (DC) supply, whose polarity stays the same.
- A 10 kΩ resistor rated at 0.25 watts or more.
- A 470 µF polarized aluminum electrolytic capacitor rated for at least 16 V.
- A break-before-make single-pole, double-throw (SPDT) switch: it connects one common terminal to either of two alternatives, never both together.
- A breadboard, wires, stopwatch and digital multimeter in DC voltage mode.
Connect the capacitor’s negative terminal to supply negative, our 0 V reference or ground (GND). Its positive terminal connects to the resistor. Connect the resistor’s other end to the switch common. The two switch choices go to +5 V and GND. Identify the switch common and capacitor polarity from their markings or datasheets before applying power. The diagram is a schematic, not a physical pin-position guide.
Connect the meter across the capacitor, red at its positive terminal and black at GND. The leads stay in the meter’s V and COM (common) sockets. The switch selects charging or discharging through the same resistor; it must never short the supply rails.
Watch one charging cycle
- With power disconnected, check the wiring and set the switch to GND. Apply 5 V and wait until the capacitor reads close to zero.
- Switch to +5 V and start the stopwatch. Record the voltage near 4.7, 9.4, 14.1 and 23.5 seconds.
- Leave it charging for at least 30 seconds. Record its final voltage and the actual supply voltage.
- Switch back to GND. Record the falling voltage at the same time intervals. Disconnect power before changing components.
| Time | Charging from 0 V | Discharging from 5 V |
|---|---|---|
| 0 s | 0.00 V | 5.00 V |
| 4.7 s | 3.16 V | 1.84 V |
| 9.4 s | 4.32 V | 0.68 V |
| 14.1 s | 4.75 V | 0.25 V |
| 23.5 s | 4.97 V | 0.03 V |
These are calculated targets for ideal components, not physical measurements. After one time constant, charging has covered about 63.2% of the remaining voltage change. After five time constants it is about 99.3% complete; “fully charged” in a practical circuit usually means close enough.
See the equations behind the table
For a capacitor initially at 0 V, Vc(t) = Vs × (1 − exp(−t / RC)). During discharge from V0, Vc(t) = V0 × exp(−t / RC). The function exp(x) means e raised to x, with e approximately 2.718. Vc is capacitor voltage, Vs is supply voltage and t is elapsed time in seconds.
Why your stopwatch may disagree
The marked capacitance has a tolerance: the actual value can differ from 470 µF. Leakage current through the capacitor can lower its eventual voltage, and the meter is another small load. A 10 MΩ meter input, meaning ten million ohms, has little effect beside a 10 kΩ resistor, but it is not infinitely large. A slowly updating meter also makes exact timing difficult.
For a fair comparison, use your measured final voltage and find when charging reaches 63.2% of that value. If it takes 5.3 seconds, estimate capacitance as C ≈ 5.3 / 10,000 = 530 µF, assuming the resistor is accurate and leakage is small. This is an estimate, not a calibrated capacitance test.
Try a different time constant
Predict what happens if R becomes 22 kΩ while C stays 470 µF. Does the final voltage double, or does the waiting time change?
Check your prediction
The ideal time constant becomes 22,000 × 0.000470 = 10.34 seconds. The final voltage still approaches 5 V; the charging is slower. An extra load or leakage can make the real final voltage lower, especially with a larger resistor.
Keep the capacitor polarity correct and discharge it through the resistor before handling it. At 5 V, the initial resistor current is only 0.5 mA and its power is 2.5 mW. Do not generalize this small experiment to high-voltage capacitors.
Continue in the interactive laboratory, or explore practical uses of capacitors. For the underlying exponential model, see OpenStax’s RC circuit discussion. Follow the polarity and voltage guidance in the Nichicon capacitor application guide and your actual component’s datasheet.