Supplier photo of an assembled infinity mirror light cube illuminated on a dark background.
Supplier photo
Temu affiliate offer · Project idea

Build an infinity light cube

Listing specifies 5-volt direct current. Soldering required; battery and glue not included.

View kit on Temu

Tricky Circuit may earn a commission through these links. Product ideas have not been bench-tested by Tricky Circuit and are not verified lesson parts lists.

Read Resistor Colour Bands: 4, 5 and 6 Bands Explained

A small resistor can carry an entire number in four painted stripes. Start with brown, black, red, gold: the first two colours make 10, red multiplies it by 100, and gold allows ±5%. The result is 1 kΩ, with a nominal tolerance interval of 950–1,050 Ω. You can learn the pattern without memorising a calculator screen.

This lesson turns an unsorted handful of leaded resistors into labelled parts. You will decode four, five and six bands, check both reading directions, and compare a prediction with an unpowered measurement. A resistor’s nominal value is its intended resistance; tolerance is the permitted initial deviation under specified conditions. Neither is a measurement of your particular part.

Three labelled resistor examples: 1 kilohm with four bands, 4.7 kilohms with five bands, and 10 kilohms with a sixth temperature-coefficient band.
Original Tricky Circuit diagram. Read the digit group before the multiplier and tolerance; use six-band TCR decoding only when the part specification confirms it. Open full size

1. Find the reading direction

Count the bands before doing arithmetic. In the conventional four-band arrangement, read two digits, a multiplier and a tolerance. Five bands use three digits before the multiplier and tolerance. A conventional six-band temperature-coefficient marking adds one more band after those five.

The first stripe is often near an end of the body; the tolerance stripe may have a larger gap before it. These are clues, not a guarantee. Gold and silver cannot be significant digits, but gold can be a multiplier, so “gold is always the last stripe” is a bad rule. Place the resistor on white paper, turn it under neutral light, and write the colour names before calculating.

Brown–black–black–brown–brown illustrates real ambiguity. One direction gives 100 × 10 = 1,000 Ω ±1%. Reversed, it gives 110 × 1 = 110 Ω ±1%. Both are syntactically plausible. A measured value near 1 kΩ helps resolve the choice; a calculator cannot identify which end of an unknown resistor the manufacturer intended. The original packet or manufacturer’s marking drawing is stronger evidence than a guess about spacing.

2. Translate colours into a number

A significant digit is one of the digits you join together before scaling. A multiplier says how many ohms each unit of that number represents. The symbol Ω means ohms; 1 kΩ is 1,000 Ω, and 1 MΩ is 1,000,000 Ω. A number such as 4.7 kΩ is 4,700 Ω, not 4.7 Ω.

Common colour-code subset used in this lesson
ColourDigitMultiplierTolerance
Black0×1—
Brown1×10±1%
Red2×100±2%
Orange3×1,000—
Yellow4×10,000—
Green5×100,000±0.5%
Blue6×1,000,000±0.25%
Violet7×10,000,000±0.1%
Grey8——
White9——
Gold—×0.1±5%
Silver—×0.01±10%

This table covers common hobby markings. A dash means “not included here,” rather than “impossible on every resistor.” The first significant digit is not black in this conventional code.

Why are some colour combinations missing?

Special tolerance colours, pink multipliers, grey/white multipliers and extra identification stripes need the exact part’s datasheet. The Yageo MFR table and Vishay’s general chart print different multiplier values for grey and white. This lesson does not resolve that documentation conflict or assume the tables are interchangeable: those multipliers are excluded from the decoder. The common black-to-violet, gold and silver multiplier values used here agree. Compare the Vishay general chart and Yageo MFR marking table, page 15; seek manufacturer clarification for an unusual part.

3. Work through four and five bands

Four bands: R = (10 × first digit + second digit) × multiplier. For yellow–violet–red–gold, join 4 and 7 to get 47, then multiply by 100. That is 4,700 Ω ±5%. Five percent of 4,700 is 235 Ω, so the interval is 4,465–4,935 Ω.

Five bands: R = (100 × first digit + 10 × second digit + third digit) × multiplier. Yellow–violet–black–brown–brown means 470 × 10 = 4,700 Ω ±1%, or 4,653–4,747 Ω. The same nominal resistance has a narrower permitted initial spread. More stripes do not imply more power handling.

Small values: red–violet–gold–gold is 27 × 0.1 = 2.7 Ω ±5%. The third gold stripe divides by ten; the fourth gold stripe specifies tolerance. With silver as the multiplier, red–violet–silver–gold becomes 0.27 Ω ±5%. Lead and contact resistance matter greatly when checking such small values.

For any example, the interval is R × (1 − t/100) through R × (1 + t/100), where t is the tolerance percentage. This is not a claim that every part changes by that amount when used, nor does it include the measuring instrument’s uncertainty.

4. What the sixth band can tell you

The temperature coefficient of resistance, abbreviated TCR, describes resistance change with temperature. It is often expressed in parts per million per kelvin, written ppm/K. A temperature difference of one kelvin is the same size as a difference of one degree Celsius. One ppm is one millionth.

For a part explicitly using the six-band TCR scheme, brown–black–black–red–brown–red represents 100 × 100 = 10,000 Ω ±1%, with a 50 ppm/K TCR code. The supported TCR colours in this lesson are brown 100, red 50, orange 15, yellow 25, blue 10 and violet 5 ppm/K. Consult the manufacturer for the coefficient’s limits and temperature range; a colour alone does not tell you the sign of every actual drift.

Using 50 ppm/K as a magnitude limit, a 40 K temperature change gives an approximate additional change of 10,000 × 50 × 40 / 1,000,000 = 20 Ω, or 0.2%. That estimate is separate from the initial ±100 Ω tolerance. It assumes the specified coefficient applies over that interval; it is not a thermal test. Vishay’s colour card also documents temperature dots and other identification marks. Not every extra stripe is a TCR stripe.

5. Try it with a meter

Use loose, undamaged axial resistors: one lead leaves each end. For a reproducible five-band sample, an example specification is Yageo MFR-25FBF52-4K7: MFR metal-film series, −25 quarter-watt body, F ±1%, B bulk packaging, F ±100 ppm/°C, 52 axial forming, 4K7 resistance. This decodes the ordering fields in the April 3, 2024 V.4 datasheet; it does not claim stock availability. Its five resistance bands are yellow–violet–black–brown–brown. Its TCR comes from its part specification, not an invented sixth stripe. Two additional loose 1 kΩ resistors let you explore parallel paths.

You also need a digital multimeter with resistance mode, its leads, two insulated clips, white paper and a pencil. No microcontroller, external supply or firmware is needed. Record your meter model and its resistance accuracy from its manual. The meter applies its own small test signal.

Resistance-mode meter with black lead in COM and red lead in the ohms socket, connected across an isolated resistor; a second drawing shows two 1 kilohm resistors in parallel.
Original connection diagram. Values in the parallel example are calculations; the meter display intentionally has no fabricated measurement. Open full size
  1. Keep the parts disconnected from all powered circuits. For a part removed from a circuit, disconnect power and discharge stored energy first; a beginner can avoid that complication by starting with loose components.
  2. Write each sample’s colours, predicted resistance and tolerance interval before measuring. Keep packaging labels available for comparison.
  3. Put the black lead in COM (the common terminal), and the red lead in the terminal marked for Ω. Select resistance mode, not the current input. Touch the probe tips together to check leads and note their residual resistance.
  4. Clip one probe to each resistor lead. Do not touch both bare leads with your fingers. Choose a suitable range if the meter does not range automatically, wait for a stable display, and record both the number and Ω/kΩ/MΩ unit.
  5. Swap the two probes. A plain isolated resistor has no polarity; a large change suggests contact trouble or that you have not isolated the component you thought you had.
  6. Compare prediction, packet and reading. A value slightly beyond a tolerance boundary needs a check of meter uncertainty and conditions before declaring the part defective.

The connection and isolation method follows Fluke’s resistance-measurement guidance. An in-circuit reading includes other paths: remove the component or disconnect one lead when you need its individual resistance.

6. Make one deliberate measurement mistake

Measure your two 1 kΩ resistors separately, calling the readings A and B. Now clip both left ends together and both right ends together, with no external power. Measure between the two joined ends. The resistors are now in parallel: both connect across the same pair of points.

Predict the new reading with A × B / (A + B). Two ideal 1,000 Ω resistors give 500 Ω. With two nominal 1 kΩ ±5% parts, the ideal parallel result spans 475–525 Ω when both extremes align. A reading near 500 Ω therefore does not mean the colour code “lied”; it describes the pair of paths your meter sees. Disconnect either resistor and the remaining part returns to its individual value.

Make a bench table with columns for sample, colours, calculated nominal, tolerance interval, measured value, meter range, and notes. Leave the measured column blank until you perform the experiment. Photograph unclear bands and keep the original labels; this is more useful than recording a guessed success.

7. What an unexpected result means

  • OL or over-range: check your meter’s meaning, range, clip contact and lead sockets. An open component is one possibility, not the only one.
  • About ten or one hundred times out: recheck multiplier colour and the display’s unit. Brown versus red is a common reading error under warm light.
  • Too low on a board: look for parallel paths. A correct individual resistor can measure low while connected to other components.
  • Low-ohm readings fluctuate: clips, lead resistance and oxidation can dominate. Use the meter’s relative/zero feature as its manual describes; do not infer a precision value from unstable contacts.
  • Both directions appear valid: compare with an isolated measurement and the exact part’s marking diagram. Arithmetic alone does not resolve this ambiguity.
Special cases: one stripe, three stripes and damaged parts

A single black band often marks a zero-ohm jumper: a link with a finite current rating and small real resistance. It is not a normal four-band code beginning with zero. In the conventional three-band scheme, the missing tolerance band denotes ±20%; do not assume a scraped-off fourth band means the same thing. Vishay’s Dale marking chart includes the missing-band convention and special military identification. If heat has changed the paint or resistance, today’s reading may not reveal the original part. Match a replacement’s power, voltage, pulse and safety characteristics from documentation, not colour alone.

8. Your challenge

Decode green–blue–orange–gold. Then explain why a nominal 1 kΩ resistor measured beside another connected 1 kΩ part could look like 500 Ω. Finally, decide whether a correctly decoded 4.7 kΩ part is automatically suitable for every 4.7 kΩ position.

Show the answers

Green 5 and blue 6 form 56; orange multiplies by 1,000. The answer is 56 kΩ ±5%, giving 53.2–58.8 kΩ. Two equal parallel paths halve the equivalent resistance. A matching number of ohms does not establish power, voltage, pulse capability or construction. For example, a hypothetical 5 V across 4.7 kΩ dissipates V²/R = 25/4,700 ≈ 5.32 mW, but a different voltage or transient changes that requirement. Colour decoding is identification of the marked resistance, not a complete replacement specification.

Verification: the colour mappings, examples and calculator are checked against the cited documents and software tests. The bench procedure is prepared for you to perform; no physical measurements or hardware tests are claimed.

Continue with What is a Resistor?, why a voltage divider drops under load, and the interactive circuit lessons.

📡Broadcast the signal — amplify the connection.

Leave a Reply

Temu affiliate offers

Find your next electronics project

Explore these do-it-yourself project kits. Check the selected option, included parts and instructions on each offer.

Tricky Circuit may earn a commission if you buy through these Temu affiliate links. These are product ideas; they have not been bench-tested by Tricky Circuit and are not verified lesson parts lists.

Supplier photo of a breadboard, jumper wires and assorted electronic components in a plastic storage case.

Supplier product photo

Try breadboard experiments

Breadboard, wires and assorted parts. Arduino controller board not included.

View kit on Temu

Supplier photo of an assembled blue surface-mount soldering practice board with a circular ring of small lights.

Supplier product photo

Solder a chasing-light board

Surface-mount soldering practice. Battery and battery holder not included.

View kit on Temu

Supplier photo of an assembled two-wheeled line-following car with a blue circuit board, two motors and an empty battery holder.

Supplier product photo

Build a line-following car

Soldering and assembly required. Check battery and track requirements before buying.

View kit on Temu