Press and release a button: an indicator stays on for about a second. Hold the same button down: the light may stay on much longer. This experiment explains the difference between a timed pulse and a trigger that is still asking the timer to run. It needs no microcontroller and no firmware.
A monostable, also called a one-shot, has one resting state and a temporary active state. Here the resting output is low. A short trigger starts the active interval immediately; this is an immediate pulse with a delayed end, not a delay before the light turns on.

Choose this particular chip
Use Texas Instruments TLC555IP, not an unspecified “555.” It is a CMOS (complementary metal-oxide-semiconductor) timer, a low-power implementation of the familiar timer function. PDIP means plastic dual in-line package: two rows of through-hole pins. The I suffix specifies the industrial temperature version and P specifies this package. The I variant’s recommended supply is 3–15 V; our regulated 3.3 V lies inside it. Its 18 V absolute maximum is a damage boundary, not a supply recommendation. Do not assume an NE555 or a different suffix shares its low-voltage behavior.
Viewed from above with the notch at the top, pins 1–4 run down the left side; pins 5–8 run up the right side. Put the package across the breadboard’s center gap. All pin numbers below refer to that top view.
Parts and equipment
- One Texas Instruments TLC555IP in the P, eight-pin plastic dual in-line package; a regulated 3.3 V supply with current limiting.
- R1: 470 kΩ, 1%; R2 and R3: 10 kΩ; R4: 10 kΩ. Ordinary 0.125 W or larger resistors are sufficient.
- C1: 2.2 µF nonpolar film timing capacitor, ±10% or better, rated at least 10 V. Avoid assuming an arbitrary electrolytic has equally low leakage.
- C2: 10 nF ceramic control-pin capacitor; C3: 100 nF ceramic bypass; C4: 1 µF ceramic bulk capacitor, each rated at least 10 V.
- Two normally open momentary buttons, one efficient red indicator LED (light-emitting diode), breadboard, short wires and a voltmeter. A scope or video recording helps compare pulse lengths.
Every connection
| Pin or part | Connection and purpose |
|---|---|
| 1 — GND | Common ground; connect supply negative here. |
| 2 — TRIG | R2, 10 kΩ to 3.3 V; S1 button to ground. Released = high; pressed = low. |
| 3 — OUT | R4, 10 kΩ in series with LED anode; LED cathode to ground. |
| 4 — RESET | R3, 10 kΩ to 3.3 V; S2 button to ground. Reset is active low. |
| 5 — CONT (control) | Sets the internal comparison levels. C2, 10 nF to ground, bypasses noise; do not wire CONT directly to a supply rail. |
| 6 — THRES (threshold) | Senses the capacitor voltage to end the interval. Connect to timing node T. |
| 7 — DISCH (discharge) | Drains C1 when OUT is low. Connect to the same timing node T. |
| 8 — VDD | Regulated 3.3 V. C3 100 nF and C4 1 µF both go from this supply to ground. |
| Timing node T | R1, 470 kΩ from 3.3 V to T; C1, 2.2 µF from T to ground. |
A pull-up resistor gives an unpressed button a defined high voltage. The bypass capacitor supplies brief local current when the chip switches; keep C3 beside pins 8 and 1. The bulk capacitor supports slower supply changes. An LED is a light-emitting diode; its series resistor limits current. With an illustrative 1.8 V red-LED drop and an ideal 3.3 V output, current is (3.3 − 1.8)/10000 = 0.15 mA. Real output voltage and brightness differ. Use an efficient indicator in modest room light; do not replace the resistor with a wire to brighten it.
Follow one complete timing cycle
- At rest, the discharge connection drains C1 and OUT is low.
- Pressing S1 pulls TRIG below its switching level. OUT rises and the discharge path opens, so C1 starts charging through R1.
- Release S1 promptly. When T reaches the timing threshold, the timer returns OUT low and discharges C1.
- Press S2 to force the output low and clear the timing capacitor. Release S1 before releasing S2 if you want to remain at rest.
The nominal trigger and timing levels are one-third and two-thirds of the supply: about 1.1 V and 2.2 V here. These are approximate internal thresholds. RESET takes priority over TRIG, and an active TRIG takes priority over the timing threshold. “Level-sensitive” means the chip responds to the continuing voltage level, not only the instant the button first moves.
Calculate the pulse, then name the uncertainty
Let R be resistance in ohms, C be capacitance in farads and t be elapsed time in seconds. The symbols exp and ln mean the exponential function and natural logarithm. For an initially discharged capacitor, the ideal charging law is VC(t) = VDD[1 − exp(−t/RC)]. At VC = 2VDD/3, this becomes t = RC ln(3), approximately 1.1RC. With R1 = 470000 Ω and C1 = 0.0000022 F, the nominal result is 1.136 seconds.
Changing only R1 to 220 kΩ gives about 0.532 seconds; changing it to 1 MΩ gives about 2.417 seconds. Disconnect power before changing parts. These predictions assume that S1 is released well before the timing interval ends and that the capacitor starts discharged.
Allowing only ±1% resistance and ±10% capacitance gives approximately 1.012–1.262 seconds for the original network. This is not a guaranteed pulse-width specification: threshold spread, temperature, capacitor leakage and the initial capacitor voltage add error. A stopwatch reaction time can also dominate a short measurement. The local calculation checks use ideal thresholds; they do not simulate every transistor in the timer.
The held-button experiment
- With power disconnected, check orientation, ground continuity and the two separate buttons. Set the supply to 3.3 V and a low current limit, for example 10 mA.
- Power on with both buttons released, then briefly press and release RESET. Startup is not a qualified power-on-reset circuit; a startup flash is not a valid timed event.
- Tap S1 for roughly a tenth of a second. Expect the LED to turn on immediately and remain on for roughly the calculated total interval, measured from the press.
- Wait for the LED to go out, then hold S1 for three seconds. Expect the LED to stay on while held and go out shortly after release: the capacitor has already passed the nominal threshold.
- Start another pulse and press RESET midway through it. The indicator should go out immediately. Record these three different behaviors, not just whether the LED ever lights.
The trigger must return high before the timing endpoint; TI specifies at least 1 µs of margin. A deliberate short tap provides a much larger margin in this seconds-scale demonstration. Contact bounce is still real: repeated presses, especially near the end, can make extra events. This circuit does not promise one clean event per physical press and is not a substitute for a debouncer.
Loading, leakage and fault checks
A meter is a load too. If a 10 MΩ meter remains connected from T to ground, it adds a parallel discharge path. In the ideal model the pulse becomes about 1.182 seconds, rather than 1.136 seconds. A 1 MΩ load changes it much more, to about 2.75 seconds. The latter is close to the condition where the capacitor cannot reach the threshold at all; actual threshold spread can change the outcome. Measure the supply and static trigger levels first, and remove the meter from T for the basic timing comparison.
If the output never goes low, first release S1 and verify TRIG is high, then check that R1 really reaches the positive supply and that pins 6 and 7 share T. A missing R1 prevents the intended charge path. If the output never rises, check RESET, LED polarity and the supply at the chip. Stop if the supply current limit operates or a part warms. Do not “test” faults by shorting OUT or reversing the supply.
This design suits visible timing experiments. It does not provide a precision clock, an edge-triggered pulse regardless of button duration, or a power stage for a relay or motor. Longer timing intervals need more attention to leakage and measurement loading, not just a bigger capacitor.
Challenge: will holding S1 for three seconds create a fresh one-second pulse when released?
No. Timing began when S1 was pressed. Once C1 has crossed the threshold, releasing the active trigger lets the output return low; release does not first discharge the capacitor and start a new full interval. RESET can discharge it, but reset is a separate operation.
Record the physical trial
Write down the full chip marking, measured supply, measured R1 and C1 if your instruments support them, pulse duration for a short tap, duration for a held button, and the response to RESET. Include the meter’s input resistance if it touches T. This article has passed source and calculation review; no physical build or measured timing is claimed.
Sources and related lessons
- Texas Instruments TLC555 datasheet, SLFS043K, January 2026: pins, operating limits and monostable operation
- Texas Instruments TLC555 product and documentation page
Continue with why a voltage divider drops under load, measuring current through a resistor with a voltmeter, and the interactive circuit lessons.